Product Description – Model CA195R-W-METER
AIR802® manufactures high performance cable. This 195-Series cable offers equivalent or better characteristics and performance than other existing industry cables such as Commscope’s WBC-195®, Times Microwave’s LMR-195®, Andrew’s CNT-195®, etc.
AIR802 CA195R-W-METER superior Low Loss 195-Series coaxial cable has a white jacket and is sold per meter. We also offer this cable by foot or in reels in either black or white jacket. This cable is manufactured with a fire retardant black polyvinyl chloride (FR-PVC) jacket. This cable is riser rated (CMR), has super flexibility.
This cable is suitable for shorter antenna cable runs.
Toepassingen
- Antenna Cable Runs to Base Stations, Access Points (AP), Bridges or CPE
- Cabling between any WiFi or WiMax antenna and the associated equipment
- Indoor or Outdoor Use
- Land Mobile Radio (LMR)
- Local MultiPoint Distribution System (LMDS)
- Multi-Channel Multi-Point Distribution Service (MMDS)
- Wireless Local Loop (WLL)
- Personal Communication Systems (PCS)
- Mobile
- Fixed Wireless
- Ham Radio
Signal Loss Comparison Chart by Cable Type
Cable Type | Attenuation (Loss) @ 2.4 GHz | Attenuation (Loss) @ 5.8 GHz |
RG-58 |
24.775 dB/100foot
81.288 dB/100meter
|
41.122 dB/100foot
134.921 dB/100meter
|
100 Series |
38.916 dB/100foot
127.685 dB/100meter
|
64.098 dB/100foot
210.307 dB/100meter
|
195 Series |
18.61 dB/100foot
61.061 dB/100meter
|
29.903 dB/100foot
98.113 dB/100meter
|
200 Series |
16.512 dB/100foot
54.178 dB/100meter
|
26.353 dB/100foot
86.464 dB/100meter
|
240 Series |
12.651 dB/100foot
41.509 dB/100meter
|
20.35 dB/100foot
66.769 dB/100meter
|
400 Series |
6.614 dB/100foot
21.703 dB/100meter
|
10.821 dB/100foot
35.504 dB/100meter
|
600 Series |
4.325 dB/100foot
14.19 dB/100meter
|
7.261 dB/100foot
23.825 dB/100meter
|
Specificaties
Cable Construction
Description |
Material |
mm |
Inches |
1.Inner Conductor | Solid Bare Copper | 0.94 | 0.037 |
2.Dielectric Foam | PE (Polyethylene) | 2.79 | 0.110 |
3.Outer Conductor | Aluminum Tape | 2.95 | 0.116 |
4.Overall Braid | 36 AWG Tinned Copper, 90% | 3.53 | 0.139 |
5.Jacket | FR-PVC White | 4.95 | 0.195 |
Mechanical Specifications
Performance Characteristics |
Unit |
US |
Metric |
Minimum Bend Radius | In. – mm | 1 | 25 |
Tensile Strength | lb – kg | 40 | 18.2 |
Cable Weight | lb/ft – kg/m | 0.021 | 0.03 |
Operating Temperature Rating | F – C | -4° to 140° | -20° to 60° |
Electrical Specifications
Performance Characteristics |
Unit |
US |
Metric |
Cutoff Frequency | GHz | 41 | 41 |
Peak Power | kW | 2.5 | 2.5 |
Velocity of Propagation | % | 80 | 80 |
Impedantie | ohms (Ù) | 50 | 50 |
Capacitance | pF/ft – pF/m | 24.3 | 79.69 |
DC Resistance – Inner Conductor | ohms/1000ft – ohms/km | 7.60 | 24.90 |
DC Resistance – Outer Conductor | ohms/1000ft – ohms/km | 4.90 | 16.10 |
Shielding Effectiveness | dB | >90 | >90 |
Jacket Spark | Volts RMS | 2500 | 2500 |
Attenuation and Average Power
Frequency (MHz) |
dB/100 Foot |
dB/100 Meter |
Av. Power (kW) |
30 | 2 | 6.5 | 0.8 |
50 | 2.5 | 8.4 | 0.68 |
150 | 4.4 | 14.6 | 0.39 |
220 | 5.4 | 17.7 | 0.32 |
450 | 7.8 | 25.5 | 0.22 |
800 | 10.5 | 34.3 | 0.15 |
900 | 11.1 | 36.5 | 0.16 |
1500 | 14.5 | 47.7 | 0.12 |
1800 | 16 | 52.5 | 0.11 |
2000 | 16.9 | 55.4 | 0.10 |
2200 | 17.8 | 58.3 | 0.09 |
2400 | 18.6 | 61.1 | 0.09 |
2500 | 19 | 62.4 | 0.09 |
3500 | 22.7 | 74.7 | 0.07 |
5800 | 29.9 | 98.1 | 0.06 |
Terminology Note: Due to various use of terminology, this cable maybe referred to as: LMR195, LMR-195, CA-195, AIR802 CA195, CFD-195, CNT-195, low loss coaxial cable, 50 ohm coaxial cable.